Newborn with abdominal distension after nasogastric tube placement Pediatric Imaging Gastrointestinal August 3, 2025August 3, 2025 CXR AP shows a nasogastric tube curling back upon itself within the esophagus with the tip of the nasogastric tube located above the thoracic inlet. The diagnosis was nasogastric tube malfunction with the nasogastric tube curled in the esophagus. Related Published August 3, 2025August 3, 2025