Infant after nasogastric tube placement

CXR of nasogastric tube in right mainstem bronchus
CXR AP shows a tracheostomy tube in normal position and a nasogastric tube whose tip is in the right lower lobe.

The diagnosis was nasogastric tube malfunction due to placement of the nasogastric tube into the trachea and right mainstem bronchus.